Adaston provides professional cavity barrier installation services across the UK, helping to stop the spread of fire and smoke through concealed spaces within buildings. Correct installation of cavity barriers is essential to maintain the integrity of compartment walls and floors, ensuring every project meets the latest building regulations and Approved Document B requirements.
Cavity barriers are a critical part of passive fire protection, preventing flames and heat from travelling through voids, wall cavities and other hidden gaps between walls, floors, ceilings, and cladding. Our team delivers high-quality installation work for new construction, refurbishments, and remediation projects.

A cavity barrier is a fire-resistant element designed to restrict the movement of fire and smoke within cavities in a building. These barriers fill voids and gaps between two masonry leaves, around door openings, and behind cladding systems to maintain the fire resistance of a compartment wall or floor.
Fire cavity barriers work by expanding under heat, sealing cavities and blocking the passage of smoke and flames. They are commonly made from intumescent materials that swell when exposed to high temperatures, creating a fire and smoke seal that protects internal cavities and maintains building integrity.
Cavity barriers are installed within wall and floor spaces, between floors, around windows and doors, and anywhere the fire strategy identifies a potential route for the spread of fire.
Get Your FREE Quotation Today
Cavity barriers play a vital role in passive fire protection systems. Without them, hidden spaces can allow flames, smoke, and heat to move rapidly through a building, compromising fire safety and endangering lives.
When correctly installed, these barriers ensure that fire remains contained within a single compartment. This allows time for occupants to evacuate and for fire services to respond. In multi-storey or complex buildings, cavity barriers are essential for protecting structural integrity and meeting legal requirements for compliance.
Fire cavity barriers are not optional; they are a legal requirement under Approved Document B and must be installed wherever concealed spaces exist. Regular inspections and maintenance help ensure the fire barrier function is maintained throughout the life of the building.
Get Your FREE Quotation TodayCavity barriers are used in a wide range of building types and locations, including:
Each location is carefully assessed as part of the building’s overall fire strategy. The correct installation method depends on the construction type, barrier material, and movement expected within the cavity space.
Our engineers identify each required location on site, ensuring barriers are positioned to restrict fire spread and maintain the fire resistance rating of each compartment.
All cavity barrier installations must comply with UK building regulations and fire safety standards. Approved Document B provides clear guidance on where cavity barriers must be fitted and how they should perform during a fire.
Our fire protection specialists ensure every installation meets these standards, maintaining compliance with the legal requirements for all types of buildings. Adaston’s teams follow third-party accredited systems, and each project is documented to demonstrate full traceability and quality assurance.
We use tested fire cavity barriers and intumescent materials that have been proven to perform under fire exposure. Every installation is inspected to verify performance, seal continuity, and long-term durability.
The installation of cavity barriers begins with a detailed survey to identify all voids, gaps, and concealed spaces. Our experts assess each cavity and specify the correct fire barrier type for the location and construction method.
Barriers are then fitted tightly within wall or floor voids to ensure a continuous seal. Edges and junctions are filled with compatible insulation and sealants to prevent the passage of fire and smoke. We ensure every product is correctly installed in line with the manufacturer’s tested systems.
Once installed, barriers are labelled, photographed, and recorded for quality control and compliance documentation. Regular inspections can then be scheduled as part of a long-term maintenance plan to confirm that all fire cavity barriers remain in good condition.
Ensure you’re compliant with Adaston!
Get in Touch

While both cavity barriers and fire stops are designed to restrict the spread of fire, they serve different functions. A cavity barrier is used to close concealed cavities such as wall and ceiling voids, whereas a fire stop seals penetrations in compartment walls or floors created by services or openings.
In simple terms, cavity barriers divide concealed spaces, while fire stopping seals individual penetrations. Both are critical elements of a building’s passive fire protection system and are required for full compliance.
Understanding the difference between a cavity barrier and a fire stop is essential for achieving a complete and effective fire protection strategy.
Get Your FREE Quotation Today
Adaston delivers high-quality cavity barrier installations backed by experience, technical expertise, and full compliance with building regulations. We provide solutions for a wide range of buildings including residential, commercial, healthcare, and education facilities.
Our services cover the full range of passive fire protection requirements, from cavity barriers and fire doors to structural steel fire protection and fire boarding. Every installation is carried out by trained professionals using tested systems and quality-assured materials.
We understand that correct installation makes the difference between containment and failure in the event of fire. That’s why we ensure every cavity, void, and concealed space is properly sealed to maintain the safety and integrity of the entire building.
If you need expert cavity barrier installation or advice on passive fire protection for your building, contact Adaston today. Our team can carry out site inspections, provide compliance advice, and deliver fully certified installations across the UK.
Protect your building, maintain compliance, and ensure the fire safety of every occupant with professional cavity barrier installation from Adaston.
Subscribe
To stay updated with industry news and regulations!
And receive your free fact sheet regarding the new 2022 regulations